Specification: | 5kgs |
---|---|
Trademark: | Ronds |
Origin: | China |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Max.channels | 16 channels vibration/temperature, 1 channel speed, 2 channels processing | |
Vibration(temperature measurement is optional) | ||
Channel No. | 16 channels | |
Sensor integrated | IEPE acceleration sensor | High/ low frequency and dual acceleration acquisition synchronously |
Input impedance | 200kΩ | |
Input coupling | AC | |
Sensor drive current | 4mA@24V | |
A/D converter | 24 bits delta-sigma ADC | |
256Hz,512Hz,1280Hz,2560Hz,5120Hz, 12.8KHz,25.6KHz,51.2KHz,102.4kHz |
||
Dynamic range | 100dB | |
Signal range | -10~10V | |
Precision | ±1%,160Hz | |
Frequency response | 0.2dB(10Hz ~ 5kHz) 0.6dB(2Hz ~ 20kHz) |
|
Integrated temperature measurement | Support | |
Temperature measurement range | -40ºC ~ 120ºC | |
Temperature measurement range | ±2ºC | |
Speed channel | ||
Channel No. | 1 channel | |
Sensor integrated | TTL isolation,12V non isolated,24V PLC isolation | |
Power output | 12VDC | |
Trigger level | 5V,12V,24V | |
Speed measurement range | (1)Against proximity switch,PLC,speed range:0 ~ 20000 RPM. (2)Against high speed encoder,incremental encoder,shaft encoder,speed range:0 ~ 10000 RPM,impulse per circle:1-2048. |
|
precision | ±0.5% | |
Sway channel(optional for wind turbine tower measurement, sensor model RH123) | ||
Channel No. | 1 channel,two axial | |
Signal range | 0~5V | |
Processing channel(optional) | ||
Channel No. | 2 channels | |
Input impedance | voltage:≥ 10kΩ current:≤ 250Ω |
|
Signal access | voltage:-10V ~ 10V current:4mA ~ 20mA |
|
precision | ±0.5% | |
Signal processing | ||
Acquire long time waveform length | 2M samples/CH | |
Acquire measurement definition length | 1K,2K,4K,8K,16K,32K,64K,128K,256K | |
Spectrum lines | 400,800,1600,3200,6400,12800,25600,51200,102400 | |
Basic parameter | ||
CPU frequency | 400MHz | |
Data storage | RAM:64M Bytes,Flash:standard 1G Bytes | |
Internet | TCP/IP,10/100baseT,optical fiber(optional) | |
communications | RS485,default 1 channel(2 channels max.) | Hardware support for oil and inclinometer incidence sensor access |
Using condition | ||
Dimension | 400mm×300mm×110mm | |
Weight | <5kg | |
IP Grade | IP65 | |
Working environment | -40~70ºC,≤95%RH,non-condensing | |
Storage environment | -50~85ºC,≤95%RH,non-condensing | |
atmospheric pressure | 70kPa ~110kPa | The highest altitude is 3000 meters |
Power supply | ||
Working voltage | Outdoor: 220VAC±20%,50~60Hz Indoor: 12-24VDC |
Need to replace transformer to support 85~135VAC |
Consumption | <8W | |
Certification | ||
Certificate | CE | |
Immunity to electromagnetic interference | ||
ESD immunity | EN61000-4-2 4 level ±8kV(contact discharge) ±15kV(air discharge) | |
Radio frequency electromagnetic radiation immunity | EN61000-4-3 3 level 10V/m | |
EFT immunity | EN61000-4-4 4 level ±4kV | |
Surge immunity | EN61000-4-5 4 level ±4kV | |
radio frequency transmission immunity | EN61000-4-6 3 level 10V | |
Magnetic field immunity | EN61000-4-8 5 level 100A/m | |
Impulse magnetic field immunity | EN61000-4-9 5 level 1000A/m | |
Damped oscillation field immunity | EN61000-4-10 5 level 100A/m | |
Voltage drop, interrupt, and voltage fluctuation immunity | EN61000-4-11 60% rated voltage 10 cycles |